Siemens' Artis Zee digital cath labs are the lastest generation in their interventional radiology line and, just as you'd expect, they offer some areas of growth and change in technology and user experience over their predecessors, the Axiom Artis labs. There is at least one thing, however, that has not changed: there are a lot of different configurations and a lot of different tubes and detectors to go with them.
That's where the guide below comes in! You can refer to the table below for descriptions and part numbers for all the X-ray tubes and detectors used on Siemens Artis Zee digital cath labs.
Artis Zee Tubes & Detectors
Before You Choose a Tube or Detector
Be aware that Artis Zee labs don't have the same naming convention as Axiom labs- the one where there's a three-letter code that tells you how it's mounted and whether it's for cardiac or angiography, à la dFC, dTA, etc. They are all simply known as "Artis Zee".
It's also worth noting that the numbers in the names of the detectors do not correlate with their size, i.e.- the Pixium 4700 is the larger 30cm x 40cm detector, while the Pixium 4800 is the smaller 20cm x 20cm detector. There is a third detector type, the Pixium 4810, which is a 20cm x 20cm detector for use only on systems with magnetic navigation (mag nav).
Detectors for Artis Zee Cath Labs
When selecting a detector, note that some detector types are intended to work with certain features like DSA or Mag Nav. If your system has these features, be sure your next detector supports them!
System(s) |
Detector Type |
Part Number |
Artis Zee Floor, Ceiling, Multi-Purpose |
Pixium 4700 High Speed 3D |
10501945 |
Artis Zee Floor, Ceiling, Multi-Purpose |
Pixium 4700 |
7555209 |
Artis Zee Floor, Ceiling |
Pixium 4800 Imp. Interface |
10501949 |
Artis Zee Floor, Ceiling |
Pixium 4800 DSA |
7555308 |
Artis Zee Floor w/ Mag Nav |
Pixium 4800 Niobe DSA |
03840761 |
Artis Zee Floor w/ Mag Nav |
Pixium 4810 Niobe Imp. Interface |
10501950 |
Tubes for Artis Zee Cath Labs
System |
Tube Type |
Part Number |
Artis Zee Floor |
Megalix Cat 125/35/80-121GW |
5764506 |
Artis Zee Floor, Ceiling, Multi-Purpose |
Megalix Cat 125/15/40/80-122GW |
5765222 |
Artis Zee Floor |
Megalix Cat Plus 125/40/90-121GW |
10144181 |
Artis Zee Floor, Ceiling, Multi-Purpose |
Megalix Cat Plus 125/20/40/80-122GW |
10144184 |
Artis Zee Ceiling |
Megalix Cat 125/35/80-122GW |
5765040 |
Artis Zee Floor w/ Mag Nav |
Megalix Cat 125/35/80-123GW |
5765404 |
Artis Zee Floor w/ Mag Nav |
Megalix Cat Plus 125/40/90-123GW |
10144182 |
